Mineral Processing
Zehra Khan; Abhishek Sharma
Abstract
Due to rapid growth in infrastructure sector, the construction of high-rise buildings is becoming very popular among all the countries. Engineers face significant issues with high rise buildings, particularly in terms of structural and foundation aspects. Many old design approaches can't be used with ...
Read More
Due to rapid growth in infrastructure sector, the construction of high-rise buildings is becoming very popular among all the countries. Engineers face significant issues with high rise buildings, particularly in terms of structural and foundation aspects. Many old design approaches can't be used with certainty since they involve extrapolation far beyond the domains of existing experience, hence structural and geotechnical engineers are being compelled to use more advanced analysis and design methodologies. The current study is an attempt to predict the bearing capacity and settlement behavior of piled-raft footing when embedded into cohesionless deposit. The numerical analysis has been carried out to examine the effect of numerous key parameters of pile and raft such as pile length (10, 15, 20 m), pile diameter (0.3, 0.4, 0.5 m), pile number (16, 20, 24), pile spacing (2D, 3D, 4D) (where “D” is diameter of the pile), raft thickness (0.4, 0.5, 0.6 m), and angle of internal friction of soil (25°, 30°, 35°) on load-settlement behavior of the piled- raft foundation using ABAQUS software. A constant spacing between the piles, i.e. 3D was used throughout the analysis. The results of numerical investigation revealed an improvement in bearing capacity and a reduction in settlement value on increasing length, diameter and number of piles and also with increasing angle of internal friction. The current study not only increases the bearing capacity of the foundation but provides a cost-effective foundation technique to engineers.
Jinwei Fu; Mohammad Reza Safaei; Hadi Haeri; Vahab Sarfarazi; Mohammad Fatehi Marji; Leige Xu; Ali Arefnia
Abstract
In this work, the mechanical behavior of strata deformation due to drilling and surface loading is investigated using a 3D physical model. For this purpose, a scaled-down physical model is first designed. Then the tunnel drilling and support system are built. The subsidence experiments performed due ...
Read More
In this work, the mechanical behavior of strata deformation due to drilling and surface loading is investigated using a 3D physical model. For this purpose, a scaled-down physical model is first designed. Then the tunnel drilling and support system are built. The subsidence experiments performed due to tunnel excavation and loading in a very dense and loose soil are performed. Soil is clayey sand (SC), and the percentages of its components are as sand (S = 1. 41%), gravel (G = 25%), and clay (C = 9.33%). Unstable tunnel support experiments are also carried out using physical simulation. Finally, deformations of soil surface and subsidence of strata are observed and recorded. In the tunnel with segmental support, 18.75% more load is applied than in the unsupported tunnel, and the total subsidence of the strata is reduced by 36.2%. The area of the deformed inner layers is decreased by 74.2%, and the length of the affected area in the largest layer is decreased by 48%. The depth of the cavity created at the surface is 46.66% less.
V. Sarfarazi; K. Asgari
Abstract
Particle Flow Code in Two Dimensions (PFC2D) was used in order to examine the influence of single tunnel and twin tunnel on the collapse pattern and maximum ground movement. Since first PFC was calibrated by the experiments, the results obtained were rendered by a uniaxial test. Further, a rectangular ...
Read More
Particle Flow Code in Two Dimensions (PFC2D) was used in order to examine the influence of single tunnel and twin tunnel on the collapse pattern and maximum ground movement. Since first PFC was calibrated by the experiments, the results obtained were rendered by a uniaxial test. Further, a rectangular model with dimensions of 100 m ˟ 100 m containing both the central tunnel and twin tunnel was built. The center of the single tunnel was placed 25 m under the ground surface, and its diameter changed from 10 m to 35 m with an increment of 5 m. The center of the twin tunnel was situated 25 m under the ground surface, and its diameter was changed from 10 m to 30 m with an increment of 5 m. For measurement of the vertical displacement, one measuring circle with a 2 m diameter was opted on the ground surface above the tunnel roof. The average of the vertical movement of discs covered in these circles was determined as a ground settlement. A confining pressure of 0.01 MPa was applied on the model. The uniaxial compression strength was 0/09 MPa; the results obtained depicted that the tunnel diameter controlled the extension of the collapse zone. Also the vertical displacement at the roof of the tunnel declined by decreasing the tunnel diameter. The ground settlement increased by increasing the tunnel diameter.
V. Sarfarazi; K. Asgari; Sh. Mohamadi Bolban Abad
Abstract
In this work, we investigate the interaction between tunnel and surface foundation in two dimensions by the particle flow code. At the first stage, the PFC calibration is conducted using the experimental test results rendered by a biaxial test. Then the simulation of a biaxial test is performed by confining ...
Read More
In this work, we investigate the interaction between tunnel and surface foundation in two dimensions by the particle flow code. At the first stage, the PFC calibration is conducted using the experimental test results rendered by a biaxial test. Then the simulation of a biaxial test is performed by confining a rectangular sample inside four walls. The walls are located at the top and bottom simulated loading plates and the adjacent walls are located at the left and right simulated sample side confinement. The velocities of the top and bottom walls are determined, and they are used for loading the sample in a strain-controlled mode. The respond of the material is evaluated by following the diverse stress and strain quantities. The axial deviatoric stress versus the axial strain for biaxial test on the bonded granular material is drawn, and then the Mohr's circle is drawn in order to reach the failure envelope of laboratory. Secondly, a rectangular model with dimensions of 10 m 10 m containing a central tunnel and a surface foundation is built. The tunnel is situated in sixteen different positions below the foundation. The foundation moves downward with a velocity of 0.016 mm/s. The results obtained show the position of the tunnel controlling the failure volume. Also the vertical displacement at the roof of the tunnel decreases by increasing the vertical spacing between tunnel and foundation. The settlement beneath the foundation increases by reducing the vertical spacing between the tunnel and the foundation. The settlement beneath the foundation decreases by augmenting the horizontal spacing between the tunnel and the foundation.
D. Mohammadi; K. Shahriar; D. Parsapour
Abstract
Tunneling in urban areas has always encountered many uncertainties, which if not considered in both analysis and design of the tunnels, will cause unexpected events during tunnel construction. Obstacles are among the most remarkable uncertainties in tunneling that affect the tunnel construction process. ...
Read More
Tunneling in urban areas has always encountered many uncertainties, which if not considered in both analysis and design of the tunnels, will cause unexpected events during tunnel construction. Obstacles are among the most remarkable uncertainties in tunneling that affect the tunnel construction process. The obstacles in urban tunneling include municipal utilities, surface and sub-surface structures, channels, wells, storages, and unknown cavities. Tehran Metro Line 7 in Iran is no exception to the rule, and has been grappling with the obstacles. In this work, we investigate the effect of the existence of wells and unknown cavities in the zone of influence of excavated tunnels by EPBM. The innovation of this research work is in the EPB tunnel design encountering wells and cavities that are as risky as the adjacent underground structure. In this work, we use a numerical simulation of the 3D finite difference method (FDM) so a series of parametric studies based on the numerical model are examined using the well and unknown cavity geometry and their location relative to the tunnel in alluvium. According to the results obtained, a major disturbance occurs in the near field of the well–tunnel, and the interaction problem happens in front of the tunnel face. The numerical outcome indicates that the most critical state of the ground settlement by EPBM happens when the well and unknown cavity are located in the face of the tunnel. It is also proved that the ground behavior is different for each part of EPBM such as ahead of the face, cutter head, shield, and segmental lining parts.
H. Haghgouei; A. Reza Kargar; M. H. Khosravi; M. Amini
Abstract
In many engineering constructions, the foundations should be built adjacent to each other. Therefore, the effect of interfering of close foundations should be considered in the design stage. In this research work, the effect of interference of closely separated foundations resting on a slope on the elastic ...
Read More
In many engineering constructions, the foundations should be built adjacent to each other. Therefore, the effect of interfering of close foundations should be considered in the design stage. In this research work, the effect of interference of closely separated foundations resting on a slope on the elastic settlement is investigated by considering a semi-analytical solution. The distribution of stress due to the footing pressure in the slope is computed by a proposed Airy stress function, and then by employing the finite difference scheme, the displacement of the footings is calculated. The results obtained show that by increasing the distance between the foundations, the interference influence on the ratio of settlement will be diminished. However, this behavior is highly linked to the slope characteristics. For a slope with a height of 10 times of footing width, beyond an S/B ratio larger than 10, the effect of interference is not tangible, and the footings behave like an isolated foundation. By decreasing the slope height, this behavior will occur at a lower S/B.
Rock Mechanics
L. Nikakhtar; Sh. Zare; H. Mirzaei Nasir Abad
Abstract
One of the main issues involved during tunnel construction with tunnel boring machines is the tail gap grouting. This gap is between the external diameter of tunnel lining and the excavation boundary that is filled with high-pressure grouting materials. In this work, three different approaches of gap ...
Read More
One of the main issues involved during tunnel construction with tunnel boring machines is the tail gap grouting. This gap is between the external diameter of tunnel lining and the excavation boundary that is filled with high-pressure grouting materials. In this work, three different approaches of gap grouting modeling in the FLAC3D software are investigated with a special attention to the influence of the grout material hardening process. In the first approach, the grout is modeled as a liquid during injection, and considering the TBM advancement and its hardening time, the grout characteristics are changed to the properties of the solid grouting. In the second approach, the grouting material from the beginning of injection is considered with the properties of solid grouting in the model, and the liquid phase is ignored. In the third approach, without considering the back-filled grouting area in the model geometry, only the injection pressure is applied to the end of the shield and behind the installed segments. The validity of the approaches is evaluated with respect to the maximum ground surface settlement. All the three approaches estimate different surface settlement but the result of the first approach is closer to the monitoring data. Also as a sensitivity analysis, in this work, we investigate the effect of the elastic modulus of liquid and solid grouting materials on the amount of surface settlement that can help to gain a more accurate insight into the effect of grout mixture.